JYWQE Automatic Mixing Sewage Pump

Scenario Usage

  1. Sewage Treatment Plant
  2. Drainage Stations for Subways, Underground Spaces, and Civil Defense Systems
  3. Sewage Discharge from Factories, Hospitals, and Residential Areas

Conditions of Use

  1. Medium temperature not exceeding 50°C, density ranging from 1.0 to 1.3 kg/m³.
  2. The motor part should be submerged in liquid at least half of its height.
  3. The pump must be operated within the specified head range to ensure that the motor is not overloaded.
No. Pump Model Rated flow (m³/h) Rated Head (m) Power (kw) Caliber (mm) Rotating Churn diameter (mm)
1 50JYWQE10-10-1200-0.75 10 10 0.75 50 2900 1200
2 50JYWQE10-12-1200-1.1 10 12 1.1 50 2900 1200
3 50JYWQE20-7-1200-1.1 20 7 1.1 50 2900 1200
4 40JYWQE12-15-1200-1.5 12 15 1.5 40 2900 1200
5 50JYWQE15-10-1200-1.5 15 10 1.5 50 2900 1200
6 50JYWQE15-15-1200-1.5 15 15 1,5 50 2900 1200
7 50JYWQE12-15-1200-2.2 12 15 2.2 50 2900 1200
8 50JYWQE15-20-1200-22 15 20 22 50 2900 1200
9 50JYWQE20-15-1200-2.2 20 15 22 50 2900 1200
10 50JYWQE25-10-1200-22 25 10 22 50 2900 1200
11 65JYWQE25-10-1200-2.2 25 10 2.2 65 2900 1200
12 80JYWQE30-8-1200-2.2 30 8 2.2 80 2900 1200
13 80JYWQE40-7-1200-2.2 40 7 22 80 2900 1200
14 50JYWQE25-15-1400-3 25 15 3 50 2900 1400
15 50JYWQE40-9-1200-3 40 9 3 50 2900 1200
16 65JYWQE25-15-1400-3 25 15 3 65 2900 1400
17 65JYWQE37-13-1400-3 37 13 3 65 2900 1400
18 80JYWQE40-10-1200-3 40 10 3 80 1450 1200
19 80JYWQE50-10-1600-3 50 10 3 80 2900 1600
20 100JYWQE60-9-1600-3 60 9 3 100 2900 1600
21 50JYWQE15-25-1200-4 15 25 4 50 2900 1200
22 50JYWQE15-30-1200-4 15 30 4 50 2900 1200
23 50JYWQE25-22-1200-4 25 22 4 50 2900 1200
24 50JYWQE40-15-1400-4 40 15 4 50 2900 1200
25 65JYWQE25-28-1400-4 25 28 4 65 2900 1200
No. Pump Model Rated flow (m³/h) Rated Head (m) Power (kw) Caliber (mm) Rotating Churn diameter (mm)
26 80JYWQE40-15-1600-4 40 15 4 80 2900 1600
27 80JYWQE43-13-1600-4 43 13 4 80 2900 1600
28 80JYWQE60-13-1600-4 60 13 4 80 2900 1600
29 100JYWQE60-12-1600-4 60 12 4 100 2900 1600
30 100JYWQE80-9-1600-4 80 9 4 100 1450 1600
31 50JYWQE25-32-1600-5.5 25 32 5.5 50 2900 1600
32 65JYWQE30-30-1600-5.5 30 30 5.5 65 2900 1600
33 80JYWQE35-25-1600-5.5 35 25 5.5 80 2900 1600
34 80JYWQE50-20-1600-5.5 50 20 5.5 80 2900 1600
35 100JYWQE65-15-1600-5.5 65 15 5.5 100 2900 1600
36 100JYWQE70-15-2000-5.5 70 15 5.5 100 1450 2000
37 150JYWQE80-10-2000-5.5 80 10 5.5 150 2900 2000
38 50JYWQE30-30-1600-7.5 30 30 7.5 50 2900 1600
39 65JYWQE40-30-1600-7.5 40 30 7.5 65 2900 1600
40 80JYWQE50-25-1600-7.5 50 25 7.5 80 2900 1600
41 80JYWQE65-25-1600-7.5 65 25 7.5 80 2900 1600
42 100JYWQE70-18-2000-7.5 70 18 7.5 100 2900 2000
43 100JYWQE100-15-2000-7.5 100 15 7.5 100 1450 2000
44 150JYWQE150-10-2000-7.5 150 10 7.5 150 1450 2000
45 150JYWQE100-12-2000-7.5 100 12 7.5 150 2900 2000
46 150JYWEQ200-7-2500-7.5 200 7 7.5 150 1450 2500
47 150JYWEQ250-6-2500-7.5 250 6 7.5 150 1450 2500
48 50JYWEQ25-50-2000-11 25 50 11 50 2900 2000
49 65JYWQE35-45-2000-11 35 45 11 65 2900 2000
50 80JYWQE40-40-2000-11 40 40 11 80 2900 2000
No. Pump Model Rated flow (m³/h) Rated Head (m) Power (kw) Caliber (mm) Rotating Churn diameter (mm)
51 100JYWQE80-20-2000-11 80 20 11 100 1450 2000
52 100JYWEQ80-22-2000-11 80 22 11 100 1450 2000
53 100JYWQE80-25-2000-11 80 25 11 100 2900 2000
54 150JYWQE150-15-2500-11 150 15 11 150 1450 2500
55 150JYWQE150-15-2500-11 150 15 11 150 2900 2500
56 200JYWQE300-7-3000-11 300 7 11 200 1450 3000
57 50JYWQE25-60-2000-15 25 60 15 50 2900 2000
58 65JYWQE40-50-2000-15 40 50 15 65 2900 2000
59 80JYWQE50-30-2000-15 50 30 15 80 2900 2000
60 100JYWQE80-30-2000-15 80 30 15 100 2900 2000
61 100JYWQE100-22-2000-15 100 22 15 100 1450 2000
62 150JYWQE200-10-2500-15 200 10 15 150 2900 2500
63 150JYWQE200-10-2500-15 200 10 15 150 1450 2500
64 200JYWQE220-12-3000-15 220 12 15 200 2900 3000
65 200JYWQE250-11-3000-15 250 11 15 200 1450 3000
66 200JYWQE300-10-3000-15 300 10 15 200 1450 3000
67 100JYWQE100-30-2000-18.5 100 30 18.5 100 1450 2000
68 150JYWQE110-30-2500-18.5 110 30 18.5 150 1450 2500
69 200JYWQE250-15-3000-18.5 250 15 18.5 200 1450 3000
70 100JYWQE100-35-2000-22 100 35 22 100 1450 2000
71 150JYWQE300-15-2500-22 300 15 22 150 1450 2500
72 150JYWQE130-30-2500-22 130 30 22 150 1450 2500
73 150JYWQE150-25-2500-22 150 25 22 150 1450 2500
74 200JYWQE200-22-3000-22 200 22 22 200 1450 3000
75 200JYWQE300-15-2500-22 300 15 22 200 1450 2500
No. Pump Model Rated flow (m³/h) Rated Head (m) Power (kw) Caliber (mm) Rotating Churn diameter (mm)
76 200JYWQE400-10-3000-22 400 10 22 200 1450 3000
77 250JYWQE600-7-3000-22 600 7 22 250 1450 3000
78 150JYWQE100-40-3000-30 100 40 30 150 1450 3000
79 200JYWQE250-22-3000-30 250 22 30 200 1450 3000
80 200JYWQE400-15-3000-30 400 15 30 200 1450 3000
81 250JYWQE600-9-3000-30 600 9 30 250 1450 3000
82 150JYWQE150-40-3000-37 150 40 37 150 1450 3000
83 200JYWQE250-30-3000-37 250 30 37 200 1450 3000
84 200JYWQE350-25-3000-37 350 25 37 200 1450 3000
85 200JYWQE400-20-3000-37 400 20 37 200 1450 3000
86 250JYWQE600-12-3000-37 600 12 37 250 1450 3000
87 150JYWQE150-48-3000-45 150 48 45 150 1450 3000
88 200JYWQE400-25-3000-45 400 25 45 200 1450 3000
89 250JYWQE600-15-3000-45 600 15 45 250 1450 3000
90 300JYWQE800-12-3500-45 800 12 45 300 1450 3500
91 300JYWQE900-10-3500-45 900 10 45 300 1450 3500
92 150JYWQE150-55-3500-55 150 55 55 150 1450 3500
93 200JYWQE250-40-3500-55 250 40 55 200 1450 3500
94 200JYWQE400-30-3500-55 400 30 55 200 1450 3500
95 250JYWQE600-20-3500-55 600 20 55 250 1450 3500
96 300JYWQE800-15-3500-55 800 15 55 300 1450 3500
97 300JYWQE1100-10-3500-55 1100 10 55 300 1450 3500
98 250JYWQE600-25-3500-75 600 25 75 250 1450 3500
99 300JYWQE800-20-3500-75 800 20 75 300 1450 3500
100 250JYWQE600-30-3500-90 600 30 90 250 1450 3500
101 300JYWQE950-20-3500-90 95 20 90 300 1450 3500

Automatic Couolina Installation