CDLFE Stainless Steel Multistage Centrifugal Pump

Product Introduction

CDLE/CDLFE is a multifunctional product that can convey various media from tap water to industrial liquids, suitable for different temperature, flow, and pressure ranges. COL is suitable for non-corrosive liquids, while CDLFE is suitable for mildly corrosive liquids.
1. Water Supply: Water plant filtration and conveyance, water plant zone water supply, main pipe boosting, high-rise building boosting.
2.Industrial Boosting: Process water systems, cleaning systems, high-pressure washing systems, and fire protection systems.
3.Industrial Liquid Conveyance: Cooling and air conditioning systems, boiler feed and condensate systems, machine tool matching, acids, and alkalis.
4. Water Treatment: Ultrafiltration systems, reverse osmosis systems, distillation systems, separators, and swimming pools.
5.Irrigation: Farmland irrigation, sprinkler irrigation, drip irrigation.

Water Pump Motor

  1. The motor is fully enclosed, air-cooled, two- pole standard motor.
  2. Protection level: IP55
  3. Insulation class: F
  4. Standard voltages:50Hz: 1×220-230/240V
    3 X 200-220/346-380V
    3 X 220-240/380-415V
    3 x 380-415V

Operating Conditions

  1. Dilute, clean, non-flammable, non-explosive liquids without solid particles or fibers.
  2. Liquid temperature: Normal temperature type -15°C to +70°C
  3. Hot water type +70°C to +120°C
  4. Ambient temperature: Maximum +40°C
  5. Altitude: Maximum 100 om

Pump Characterisrics

CDLE/CDLFE is a non-self-priming vertical multistage centrifugal pump designed for the installation of standard motors. The motor shaft is directly connected to the pump shaft through a coupling, and tie bolts fix the pressure-resistant cylinder and the flow components between the pump head and the inlet and outlet sections. The pump inlet and outlet are on the same line at the bottom of the pump. This pump can be equipped with an intelligent protection device as needed to provide effective protection against dry running, phase loss, overload, and other issues.

Model Significance

No. Pump Model (DN25) Power (kw) Head (m)
1 2-20 0.55 15
2 2-30 0.55 22
3 2-40 0.55 30
4 2-50 0.55 -
5 2-60 0.55 45
6 2-70 0.55 52
7 2-80 1.1 59
8 2-90 1.1 67
9 2-100 1.1 74
10 2-110 1.1 82
11 2-120 1.5 90
No. Pump Model (DN25) Power (kw) Head (m)
12 2-130 1.5 98
13 2-140 1.5 105
14 2-150 1.5 112
15 2-160 1.5 120
16 2-170 1.5 128
17 2-180 2.2 136
18 2-190 2.2 143
19 2-200 2.2 150
20 2-210 2.2 157
21 2-220 2.2 165
22 2-230 3 173
No. Pump Model (DN25) Power (kw) Head (m)
23 2-240 3 181
24 2-260 3 189
25 2-250 3 198
No. Pump Model (DN32) Power (kW) Head (m)
1 4-20 0.55 15
2 4-30 0.55 24
3 4-40 0.75 32
4 4-50 1.1 40
5 4-60 1.1 48
6 4-70 1.5 56
7 4-80 1.5 64
8 4-90 2.2 72
9 4-100 2.2 81
10 4-110 2.2 88
11 4-120 2.2 95
No. Pump Model (DN25) Power (kW) Head (m)
12 4-130 3 103
13 4-140 3 112
14 4-150 3 120
15 4-160 3 129
16 4-170 4 137
17 4-180 4 145
18 4-190 4 153
19 4-200 4 161
20 4-210 4 169
21 4-220 4 178
No. Pump Model (DN40) Power (kW) Head (m)
1 8-20 0.75 18
2 8-30 1.1 28
3 8-40 1.5 36
4 8-50 2.2 45
5 8-60 2.2 54
6 8-70 3 64
7 8-80 3 73
No. Pump Model (DN40) Power (kW) Head (m)
8 8-90 4 83
9 8-100 4 92
10 8-110 4 101
11 8-120 4 111
12 8-130 5.5 119
13 8-140 5.5 130
14 8-150 5.5 138
No. Pump Model (DN40) Power (kw) Head (m)
1 8-160 5.5 148
2 8-170 7.5 156
3 8-180 7.5 167
4 8-190 7.5 175
5 8-200 7.5 186
No. Pump Model (DN40) Power (kW) Head (m)
1 12-20 1.5 20
2 12-30 2.2 30
3 12-40 3 40
4 12-50 3 50
5 12-60 4 60
6 12-70 5.5 70
7 12-80 5.5 80
8 12-90 5.5 90
9 12-100 7.5 100
10 12-110 7.5 110
11 12-120 7.5 120
12 12-130 7.5 130
13 12-140 11 140
14 12-150 11 150
15 12-160 11 160
16 12-170 11 170
17 12-180 11 180
No. Pump Model (DN50) Power (kW) Head (m)
1 16-20 22 23
2 16-30 3 35
3 16-40 4 47
4 16-50 5.5 59
5 16-60 5.5 70
6 16-70 7.5 82
7 16-80 7.5 96
8 16-90 11 108
9 16-100 11 120
10 16-110 11 132
11 16-120 11 144
12 16-130 15 156
13 16-140 15 165
14 16-150 15 177
15 16-160 15 189
No. Pump Model (DN50) Power (kW) Head (m)
1 20-10 1.1 10
2 20-20 2.2 23
3 20-30 4 35
4 20-40 5.5 47
5 20-50 5.5 58
6 20-60 7.5 70
7 20-70 7.5 82
8 20-80 11 94
9 20-90 11 106
10 20-100 11 118
11 20-110 15 130
12 20-120 15 142
13 20-130 15 154
14 20-140 15 166
15 20-150 18.5 178
16 20-160 18.5 190
17 20-170 18.5 202
No. Pump Model (DN65) Power (kW) Head (m)
1 32-10 2.2 13
2 32-20 4.0 28
3 32-30 5.5 42
4 32-40 7.5 56
5 32-50 11 72
6 32-60 11 86
7 32-70 15 102
8 32-80 15 115
9 32-90 18.5 132
10 32-100 16.5 145
11 32-110 22 161
12 32-120 22 176
13 32-130 30 193
14 32-140 30 208
No. Pump Model (DN80) Power (kW) Head (m)
1 42-10 40 19
2 42-20 75 38
3 42-30 11 59
4 42-40 15 80
5 42-50 18.5 101
6 42-60 22 122
No. Pump Model (DN80) Power (kW) Head (m)
7 42-70 144 30
8 42-80 164 37
9 42-90 187 37
10 42-100 205 45
11 42-110 229 45
12 42-120 250 45
13 42-130 262 45
No. Pump Model (DN100) Power (kW) Head (m)
1 65-10 5.5 20
2 65-20-2 7.5 26
3 65-20-1 11 33
4 65-20 11 40
5 65-30-2 15 46
6 65-30-1 15 53
7 65-30 18.5 60
8 65-40-2 18.5 66
9 65-40-1 22 73
10 65-40 22 80
11 65-50-2 30 88
12 65-50-1 30 95
13 65-50 30 102
14 65-60-2 30 110
15 65-60-1 37 117
16 65-60 37 124
17 65-70-2 37 132
18 65-70-1 37 139
19 65-70 45 146
20 65-80-2 45 154
21 65-80-1 45 161
No. Pump Model (DN100) Power (kW) Head (m)
1 85-10-1 5.5 14
2 85-10 7.5 20
3 85-20-2 11 30
4 85-20 15 43
5 85-30-2 18.5 52
6 85-30 22 65
7 85-40-2 30 76
B 85-40 30 88
9 85-50-2 37 98
10 85-50 37 112
11 85-60-2 45 136
12 85-60 45 123
No. Pump Model (DN125) Power (kW) Head (m)
1 120-10 11 19
2 120-20-2 15 29
3 120-20-1 18.5 35
4 120-20 22 40
5 120-30-2 30 49
6 120-30-1 30 56
7 120-30 30 61
8 120-40-2 37 69
9 120-40-1 37 76
10 120-40 45 81
11 120-50-2 45 90
12 120-50-1 45 97